Skip to content

New website. Enquiries and messages reach us, but no email receipt is sent yet.

Magnetic separator (grid/housing)

Magnetic separator, semi-automatic

Magnetic separator with semi-automatic cleaning that removes ferrous particles from powders and granules in gravity flow. Four sizes.

Pless no.
MS-400001
Range
4 standard sizes, configured on enquiry
Product area
Magnetic separation

Magnetic separator for gravity flow that captures ferrous contamination in free-flowing powders and granules. The product passes magnetic bars mounted in a housing, and the metal particles are held on the bars.

Cleaning is semi-automatic, so collected metal can be removed quickly without a long production stop.

Main features

  • Four standard sizes, F150 to F300, with 5–11 magnets
  • Made of stainless steel SS316L, with a silicone gasket
  • Magnetic bars 25 mm in diameter, magnet grade N48H
  • Fitted with a safety switch

Choices in the enquiry

In the enquiry you can choose a flange adaptor for a round connection (NW80–NW400) and state whether you want a collector plate, a gasket or a hygienic design. To give the right recommendation we also ask for information about the product to be separated, particle size, required throughput and installation geometry.

Choose and send enquiry

Choose the size by the connection where the separator will be fitted. Pless assesses whether semi-automatic cleaning suits your product and your quantity.

1 Choose a size

The size follows the connection in the chute or outlet. If you don't know, give the dimensions of the connection below and we will choose.

See all technical data for the sizes
Compare only:
Magnetic separator, semi-automatic: sizes compared
PropertyMagbox SA F150Magbox SA F200Magbox SA F250Magbox SA F300
Dimensions
Weight (kg)27.3534.44–54.58
Performance
Number of magnets (pcs)57911

2 About your product

Answer what you know. Everything is optional, and “don't know” is a good answer.

Form
How does the product flow?
More questions for a more precise quotation (6)
What needs to be removed?You can choose more than one.
°C
Is there explosive dust or an explosive atmosphere (ATEX)?
How often can the separator be cleaned?

3 Construction

Choose what you know. Anything you leave open, we clarify in the quotation.

Flange adaptor (NW)

4 Options

Collector plate required
Gasket required
Hygienic design required

Technical data

Dimensions

Filter bar diameter
25 mm

Performance

Magnet grade
N48H
Minimum flux density
12,000 Gs

Material

Body material
SS316L
Surface treatment
Sublimation
Gasket material
Silicon
Surface roughness Ra
32-4 µin

Safety

Safety switch type
Schmersal EEX AZ16-12 ZVRK
Voltage (as stated by the manufacturer)
230 VAC / 24 VDC (2x NC / 1x NO)

Installation

Installation type
gravity-fed (free-flowing powders and granules)
Cleaning method
semi-automatic