Rotary valve series RS/ex
RS rotary valve in ex version, flameproof and pressure-shock resistant up to 10 bar to EN 15089, for potentially explosive areas. Six sizes (RS/ex180–RS/ex450).
- Pless no.
- CS-490005
- Range
- 6 standard sizes, configured on enquiry
- Product area
- Material handling, valves and metering
Choose and send enquiry
A rotary valve is chosen by what it has to do, how much product has to pass through per hour and what kind of product it is. We go through the information you give and find the right size together with you.
1 What will the valve do?
Answer what you know. Everything is optional, and “don't know” is a good answer.
More questions for a more precise quotation (7)
2 Choose a size
The volume per revolution is the manufacturer's stated value at 100 % filling. How much the valve delivers per hour depends on the product's bulk density, the degree of filling and the speed. We work that out together with you.
See all technical data for the sizes
| Property | RS/ex180 | RS/ex230 | RS/ex270 | RS/ex300 | RS/ex350 | RS/ex450 |
|---|---|---|---|---|---|---|
| Dimensions | ||||||
| Size | 180 | 230 | 270 | 300 | 350 | 450 |
| Inlet opening (mm) | 190 × 118 | 238 × 135 | 276 × 148 | 340 × 198 | 470 × 238 | 570 × 285 |
| Outlet opening (mm) | 190 × 118 | 235 × 135 | 276 × 158 | 340 × 198 | 476 × 220 | 570 × 285 |
| Gross weight (kg) | 73 | 103 | 145 | 202 | 330 | 600 |
| Performance | ||||||
| Capacity per revolution (l/rev) | 3 | 7 | 12 | 18 | 34 | 71 |
| Number of rotor blades | 11 | 11 | 11 | 11 | 12 | 12 |
3 Construction
The standard choice is marked. If you are not sure, leave the choice open and we clarify it together with you.
4 Options
Technical data
Performance
- Duty class
- Medium / heavy duty
- Application
- Flameproof / explosion isolation system
- Max differential pressure
- 0.1 bar
- Min operating temperature
- -20 °C
- Max operating temperature (standard)
- 40 °C
Material
- Housing material (standard)
- GS400 cast iron housing and covers
Safety
- Flameproof explosion isolation
- Explosion Isolation System EN 15089: flameproof and pressure surge-resistant up to 10 bar (steel or stainless steel blades); MIE ≥ 10 mJ
Installation
- Bearings (standard)
- Ball bearings (external supports with external ball bearings possible)