Skip to content

New website. Enquiries and messages reach us, but no email receipt is sent yet.

Rotary valve

Rotary valve series VPR

General-purpose drop-through rotary valve with round inlet and good air tightness, also for feeding pneumatic conveying lines. Seven sizes (VPR100–VPR400), maximum differential pressure 1 bar.

Pless no.
CS-490003
Range
7 standard sizes, configured on enquiry
Product area
Material handling, valves and metering

Choose and send enquiry

A rotary valve is chosen by what it has to do, how much product has to pass through per hour and what kind of product it is. We go through the information you give and find the right size together with you.

1 What will the valve do?

Answer what you know. Everything is optional, and “don't know” is a good answer.

Use
kg/m³
More questions for a more precise quotation (7)
°C
Is there explosive dust or an explosive atmosphere (ATEX)?
Relevant when feeding into pneumatic conveying.
bar
Is the product in contact with food, feed or pharmaceuticals?
How often must the valve be cleaned inside?
Is the product abrasive?

2 Choose a size

The volume per revolution is the manufacturer's stated value at 100 % filling. How much the valve delivers per hour depends on the product's bulk density, the degree of filling and the speed. We work that out together with you.

See all technical data for the sizes
Compare only:
Rotary valve series VPR: sizes compared
PropertyVPR100VPR180VPR230VPR270VPR300VPR350VPR400
Dimensions
Size100180230270300350400
Inlet opening (mm)Ø70Ø120Ø150Ø180Ø220Ø300Ø350
Outlet opening (mm)Ø70150 × 120185 × 148242 × 180266 × 218360 × 250400 × 320
Gross weight (kg)156182113158244295
Performance
Capacity per revolution (l/rev)0.53611173045
Number of rotor blades68888810

3 Construction

The standard choice is marked. If you are not sure, leave the choice open and we clarify it together with you.

4 Options

Additional optionsYou can choose more than one.

Technical data

Performance

Principle
Drop-through rotary valve
Duty class
Heavy duty
Application
Under cyclones, filter, gravity systems or pneumatic conveying inlet
Max differential pressure
1 bar
Min operating temperature
-15 °C
Max operating temperature (standard)
60 °C
Max operating temperature (heat-resistant)
220 °C

Material

Housing material (standard)
Cast iron housing and covers
Standard colour
RAL 9001

Safety

ATEX marking
CAT II 1/**D Ex h IIIC T135°C (**2 of 3), zone 21 or 22, possible as option
Flameproof explosion isolation
Not available as flameproof version (VDL refers to RS, ExR, HT and HT-S)

Installation

Bearings (standard)
Ball bearings (external supports with outside ball bearings possible)

Certification

Food contact
EC Regulation 1935/2004 material compatibility available on request